Static flow meters for thermal energy C&I applications
Axonic is a static ultrasonic flow meter perfectly adapted to the needs of district heating and cooling applications. With our proven know-how of static metering technology it has been developed for heating and cooling applications where water is used as an energy transfer medium.
Axonic is equipped with an universal interface which allows it to be easily combined with Itron calculators such as CF51, CF55 or CF800. It is powered by the connected calculators and therefore it doesn’t require its own source of electrical power (e.g. battery).
Revenue protection
Axonic helps to protect the revenue of district heating companies by featuring extraordinary metrological performance, such as a high accuracy according to MID class 2 , long term stability and an outstanding dynamic range up to R400. AXONIC is still measuring also when exceeding qmax and helps reducing billing losses.
In addition, the fully concentric flow channel design creates a flow profile that is insensitive against up, and downstream flow disturbances and therefore reliable in any type of installation, even if space for flow meter installation is very limited. In combination with Itron calculators it features intelligent diagnostic functions to control and optimize the entire thermal energy system.
Advanced functions
In the field the Axonic flow meter permanently monitors the operating conditions. In case of abnormal conditions, such as back-flow or air in the pipe, the meter sends a dedicated warning to the connected Itron calculator that can be transmitted via advanced reading systems in order to prompt a quick response by the system operator.
Type | DN 65 /qp 25 | DN 80 /qp 40 | DN 100 /qp 60 | DN 125 /qp 100 | DN 150 /qp 150 | |
---|---|---|---|---|---|---|
Maximum overflow | qss (m3/h) | 55 | 88 | 132 | 220 | 330 |
Maximum flow | qs (m3/h) | 50 | 80 | 120 | 200 | 300 |
Nominal flow | qp (m3/h) | 25 | 40 | 60 | 100 | 150 |
Minimum flow (R250) | qi (l/h) | 100 | 160 | 240 | 400 | 600 |
Cut off flow | qc (l/h) | 40 | 80 | 100 | 200 | 300 |
Dynamic range (approval) | 400H / 250V | 250 H,V | 250 H,V | 250 H,V | 250 H, 100 V | |
Accuracy class | EN1434 class C2 | EN1434 class C2 | EN1434 class C2 | EN1434 class C2 | EN1434 class C2 | |
Head loss qp | bar | ≤ 0,10 | ≤ 0,17 | ≤ 0,13 | ≤ 0,22 | ≤ 0,15 |
Flow profile sensitivity class | U0D0 | U0D0 | U0D0 | U0D0 | U0D0 | |
Water temperature (heat version) | °C | 1… 130°C/150°C (permanent / accidental) | 1… 130°C/150°C (permanent / accidental) | 1… 130°C/150°C (permanent / accidental) | 1… 130°C/150°C (permanent / accidental) | 1… 130°C/150°C (permanent / accidental) |
Water temperature (cooling version) | °C | 1… 50°C | 1… 50°C | 1… 50°C | 1… 50°C | 1… 50°C |
Ambient temperature | °C | -25°C … +60°C | -25°C … +60°C | -25°C … +60°C | -25°C … +60°C | -25°C … +60°C |
Storage / transport temperature | °C | -25°C … +60°C | -25°C … +60°C | -25°C … +60°C | -25°C … +60°C | -25°C … +60°C |
Pulse output (pulse A and B) | |
---|---|
Type | open collector (drain) |
Polarity | non-reversible (see manual) |
Pulse-length | ≥ 5ms, optional up to 500ms (value indicated in type plate) |
Max. input voltage | 30V DC |
Max. input current | 27mAv |
Drop off Voltage (ON) | <0,3 at 0,1 mA / < 2V at 27mA |
Resistance (OFF state) | 6 MΩ |
Max. output frequency | 128 Hz |
Pulse weight options | 8 p/L up to 2500 L/p (value indicated on type plate) |
Type | DN 65 qp25 PN16 | DN 65 qp25 PN25 | DN 65 qp25 PN40 | DN80 qp 40 PN16 | DN80 qp 40 PN25 | DN80 qp 40 PN40 | DN100 qp 60 PN16 | DN100 qp 60 PN25 | DN100 qp 60 PN40 | DN125 qp 100 PN16 | DN150 qp 150 PN16 | DN150 qp 150 PN25 | DN150 qp 150 PN25 | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Body length (available versions) | L1 | mm | 200 300 | 300 | 300 | 200 225 300 350 | 300 | 350 | 250 360 400 | 360 | 400 | 250 | 300 500 | 500 | 300 |
Electronic | L2 B | mm mm | 124 119 | 124 119 | 124 119 | 124 119 | 124 119 | 124 119 | 124 119 | 124 119 | 124 119 | 124 119 | 124 119 | 124 119 | 124 119 |
Height | A1 A2 | mm mm | 204 93 | 204 93 | 204 93 | 209 100 | 209 100 | 209 100 | 219 111 | 219 118 | 219 112 | 219 94 | 244 143 | 244 150 | 244 144 |
Bolt circle diameter | K | mm | 145 | 145 | 145 | 160 | 160 | 160 | 180 | 190 | 190 | 210 | 240 | 250 | 250 |
Bolt holes diameter | L | mm | 19 | 19 | 18 | 19 | 19 | 18 | 20 | 23 | 22 | 20 | 24 | 28 | 26 |
Number of holes | 4 | 8 | 8 | 8 | 8 | 8 | 8 | 8 | 8 | 8 | 8 | 8 | 8 | ||
Flange dimensions* | D D1 F1 F2 | mm mm mm mm | 185 108 – – | 185 108 – – | 188 109 178 175 | 200 128 – – | 200 128 – – | 203 120 194 190 | 220 156 – – | 235 156 – – | 238 149 228 224 | 250 184 – – | 285 216 – – | 300 216 – – | 300 203 288 288 |
Weight (length) | kg (mm) | 8,0 (200) 9,0 (300) | 9,0 (300) | 10,5 (300) | 9,3 (200) 9,6 (225) 10,4 (300) 10,9 (350) | 10,4 (300) | 14,0 (350) | 13,0 (250) 14,0 (360) 15,0 (400) | 16,0 (360) | 20,0 (400) | 11,77 (250) | 24,0 (300) 28,0 (500) | 31,0 (500) | 32,0 (300) |
*Flanges PN16 and PN 25 according EN 1092-2 / Mobile Flanges Elevated interface type B